Quickstart Guide to ordering Handicare / Savaria Track Accessories for both fixed and portable Patient Ceiling Lifts by Mark Felling. Also applies to Prism Medical, Waverly Glen, Medcare, Arjo, and most other brands.
- add On-track Charging Accessory (1st 3 lines) for your lift model. A traditional SLA (Sealed Lead Acid) or new Lifepo4 (Lithium Iron Phosphate) Batteries and Charger Kit will also be required (see Complementary Items)
- add 1 Track End Stop with Pin (360460) for opposite end of the track from a Charging Track End Stop. Add 2 when used with OMNI Constant Charging Transtrip or a Mid-Track Charging Station.
Decide between mounting to the ceiling or suspending from wall-to-wall which may be more acceptable in rentals where holes in sheetrock walls can be filled after moving out similar to hanging a picture or TV mount on the wall. A maximum of 26′ can be spanned with TrackPlus with 300 lb capacity or 21′ with 450 lb capacity. 2 Post Wall Mount System (342100) or Heavy Duty Wall Mount Brackets Kit (360809) are available or Free-Standing Track Systems.
How many 3″ Ceiling Brackets (360461) are needed depends on your installation, track type, and weight capacity requirements. For 450 lb to 600 lb with Standard Track:
Bottom-up installation screwed directly into studs perpendicular to the track requires 1 GRK RSS Structural Screw (90307) for each 3″ bracket:
- 20″ on center requires (1) 3″ bracket every 20″ of track +1
- 16″ on center studs require (1) 3″ bracket every 32″ of track +1
Top-down installation between studs parallel to the track requires every 2 ft or 24″: (1) Home Care Hardware Kit (360704) or 2×6 wood block mounted between the studs with 2 structural joist hangers plus
- (1) 3″ Ceiling Bracket every 24″ of track + 1 on end
- (3) 3″ Ceiling Brackets for 90-degree (max every 24″) and 45-degree curves (max every 38″) + appropriate (see #5) 6″ Connector Bracket(s) on either end
If a ceiling is not level, add 2mm, 3/8″, or 1″ Aluminum shims between ceiling and 3″ brackets. For TIG trusses, commercial suspended ceilings, track suspended from a vaulted ceiling, or other special applications, contact us for a free with order custom detailed design.
Also available: 3” Ceiling Bracket Assembly (1/2″ Slot) 360478 for commercial suspended track installs
- add (1) 6″ Connector Bracket (360462) for each point where two pieces of straight track but into each other. A 6″ Connector Bracket is also needed where a piece of curved track butts into a piece of straight track (or a 2nd piece of curved track). Determine if it is an Outside Profile Curve (360464) or Inside Profile Curve (360465) using this photo as a guide.
- Finally, add optional cosmetic End Caps for your type of track.
Example Bundle of everything needed to mount 8′ pc of Track
- (4) 360461 3” Ceiling Bracket Assembly (3/8″ Slot) – 4 per 8′ pc of track
- (4) 5/16″ x 3-1/2″ GRK’s RSS™ Rugged Structural Torx Screw – bottom up direct to perpendicular studs
- (2) 360460 Track End top w/pin & ring (can substitute 3/8″x3″ bolt & nut)
- (2) 360419 Standard Track White Molded Styrene End-cap (cosmetic not required)